MyDay Multifocal fitting offers a simplified, highly effective approach for practitioners, backed by OptiExpert support and proven clinical success with habitual lens wearers.
This guide details a streamlined process for achieving optimal vision and comfort with these daily disposable lenses, addressing modern visual demands.
What are MyDay Multifocal Lenses?
MyDay Multifocal lenses are daily disposable contact lenses designed to correct presbyopia, offering clear vision at multiple distances – far, intermediate, and near. Utilizing CooperVision’s Binocular Progressive design, these lenses provide a smooth transition between focal points.
Crafted from kalifilcon A material with Aquaform Technology, they prioritize hydration and comfort throughout the day. They are ideal for individuals seeking a convenient and healthy vision correction option, avoiding the need for reading glasses.
Benefits of MyDay Multifocal Lenses
MyDay Multifocal lenses deliver exceptional visual clarity at all distances, reducing reliance on glasses. Their daily disposable format promotes optimal eye health and minimizes deposit build-up, enhancing comfort. Aquaform Technology ensures lasting hydration, combating digital eye strain.
The lenses boast a high success and satisfaction rate, simplifying fitting with OptiExpert tools. They offer a convenient, healthy, and effective solution for presbyopic patients seeking seamless vision correction.
Pre-Fitting Assessment
A comprehensive eye exam is crucial, including refraction and visual needs analysis. Assess viewing distances to understand patient lifestyle and optimize MyDay Multifocal fitting.
Comprehensive Eye Examination
Prior to fitting, a thorough eye examination is paramount. This includes evaluating overall ocular health, assessing corneal topography, and measuring tear film dynamics. Accurate refraction, encompassing both distance and near vision, is essential for determining the initial lens power.
Detailed patient history, including previous contact lens wear and any systemic conditions, should be documented. This holistic approach ensures a successful MyDay Multifocal fitting experience, tailored to individual needs.
Refraction and Visual Needs Analysis
Accurate refraction, beyond a standard chart, is crucial. Determine the best spectacle correction, then monocular and binocular acuities at distance and near. Analyze the patient’s visual demands – near work duration, computer use, and driving habits – to understand their specific needs.
Identify any astigmatism and assess add power requirements. This detailed analysis informs the initial MyDay Multifocal lens selection, maximizing visual comfort and clarity.
Assessment of Viewing Distances
Evaluate typical viewing distances for both distance and near tasks. For distance, observe vision in the natural environment with normal lighting. For near, utilize a handheld device or reading material to assess clarity at the patient’s preferred reading distance.
Understanding these distances is vital for selecting the appropriate MyDay Multifocal design and ensuring optimal vision at all focal points.

Trial Lens Selection
Selecting initial power and add values considers refraction, visual needs, and lifestyle. MyDay Multifocal fitting prioritizes a straightforward approach for successful outcomes.
Determining Initial Power
Begin with the patient’s current single vision distance prescription. Refine based on refraction results, prioritizing best corrected distance visual acuity. For established contact lens wearers, utilize their most recent successful prescription as a starting point.
Carefully assess binocular balance and consider any existing astigmatism. MyDay Multifocal fitting emphasizes a personalized approach, so slight adjustments may be necessary to optimize clarity and comfort during the trial phase.
Selecting Appropriate Add Power
Initiate add power selection based on the patient’s age and reported near vision demands. A lower add power is often preferred for younger presbyopes or those with significant accommodative ability. Conversely, higher adds suit older patients or those needing substantial near correction.
Consider lifestyle factors; extensive near work may necessitate a stronger add. Start with a conservative add and adjust during subjective refinement to achieve optimal near vision without compromising distance clarity.
Considering Patient Lifestyle
Patient lifestyle profoundly impacts MyDay Multifocal fitting success. Individuals heavily engaged in prolonged digital device use may benefit from lenses optimized for intermediate distances, minimizing digital eye strain. Active lifestyles demand robust vision at all ranges, requiring careful balance.
Assess typical viewing distances and activities to tailor the lens design. Understanding these needs ensures optimal visual performance and patient satisfaction throughout their daily routines.

Fitting Process
Dispense trial lenses and conduct a thorough subjective refinement, evaluating vision at distance, intermediate, and near to ensure optimal clarity and comfort.
Trial Lens Dispensing
Following assessment, dispense a pair of MyDay Multifocal trial lenses, ensuring the patient understands proper insertion, removal, and wearing schedule; Encourage full-day wear under normal conditions.
Emphasize the importance of reporting any sensations – haloes, glare, or blurriness – experienced during the trial period. A successful trial relies on honest patient feedback for subsequent refinement.
Provide clear instructions for lens care and follow-up appointment scheduling.
Subjective Refinement
After trial lens wear, conduct a thorough subjective refraction, questioning the patient about clarity at distance, intermediate, and near. Utilize a binocular balance assessment to optimize vision.
Adjust add power in 0.25D increments, prioritizing comfortable near vision without compromising distance acuity. Address any reported haloes or glare through power adjustments or lens design considerations.
Confirm patient satisfaction with all viewing distances before finalizing the prescription.

Lens Optimization
Optimize vision by refining distance, near, and intermediate acuity. Adjust add power incrementally, balancing clarity across all viewing distances for optimal patient comfort.
Distance Vision Optimization
Assess distance vision in a typical environment with normal lighting. Ensure clear sight at far distances, crucial for driving and general daily activities. If blurry, consider slight adjustments to the distance power.
Prioritize monocular clarity, then binocular balance. Remember, successful multifocal fitting requires a holistic approach, ensuring comfortable and functional vision at all distances. Utilize diagnostic sets for precise refinement.
Near Vision Optimization
Evaluate near vision using a handheld device or reading material at a comfortable distance. Confirm clear and comfortable reading without excessive accommodation. If blur persists, incrementally increase the add power, monitoring for optimal clarity.
Balance near acuity with distance performance; avoid over-plus. Patient feedback is vital – prioritize their subjective experience for successful near vision optimization and overall satisfaction.
Intermediate Vision Optimization
Assess intermediate vision at a typical computer working distance. Ensure clarity for tasks like screen viewing and reading instruments. Adjust power if needed, considering the patient’s specific needs and work environment.
Fine-tune the lens design to balance distance and near vision, achieving comfortable and functional intermediate sight. Prioritize patient feedback to optimize performance for digital device use.
Troubleshooting Common Issues
Address haloes, glare, or blurry vision through careful refraction refinement and lens adjustments. Patient adaptation is key; monitor and provide support.
Haloes and Glare
Haloes and glare can occur during MyDay Multifocal adaptation, often linked to initial power or add power selection. Refine the prescription, considering a slight reduction in add power or adjusting lens centration.
Ensure proper fitting and assess corneal health. If symptoms persist, explore alternative lens designs or consider a trial with a different add power to minimize light scattering and improve visual clarity, especially in low-light conditions.
Blurry Vision
Blurry vision with MyDay Multifocal lenses often indicates a need for subjective refinement. Carefully reassess distance and near vision, adjusting the add power in small increments.
Verify proper lens centration and rule out corneal irregularities. A comprehensive refraction and visual needs analysis are crucial. If blur persists, consider a trial with a different lens parameter or explore alternative multifocal designs.
Adaptation Challenges
Adaptation to MyDay Multifocal lenses can sometimes present challenges for patients, particularly those new to multifocal contact lenses. Encourage consistent wear and patience during the initial fitting period.
Address any concerns regarding vision fluctuations or discomfort. Reassure patients that a period of adjustment is normal, and further refinement may be necessary to optimize their visual experience.
Aquaform Technology Explained
Aquaform Technology within MyDay lenses stores water throughout the entire lens material, from core to surface, ensuring lasting hydration and comfort all day long.
Hydration and Comfort
MyDay lenses, utilizing Aquaform Technology, maintain a high water content throughout the entire lens matrix. This unique feature isn’t limited to the surface; water is integrated within the material itself.
Consequently, the lenses resist drying, providing consistent comfort even during extended wear. This consistent hydration minimizes end-of-day dryness and irritation, crucial for multifocal lens adaptation and overall patient satisfaction.
Material Properties
MyDay Multifocal lenses are crafted from kalifilcon A, a silicone hydrogel material known for its high oxygen permeability. This allows for healthy corneal oxygenation, even with multifocal designs.
The material’s inherent wettability contributes to exceptional comfort, while its stability ensures consistent lens performance throughout the day. This combination of properties supports optimal vision and a positive wearing experience.

Clinical Study Results
MyDay Multifocal demonstrated high effectiveness and success rates in a study of 58 habitual multifocal wearers, with positive patient satisfaction reported.
Effectiveness and Success Rates
MyDay Multifocal lenses consistently showed a high degree of success in fitting, proving easy to adapt to for many patients. A prospective study involving habitual multifocal contact lens wearers indicated positive outcomes; The kalifilcon A material contributed to clear visual results, and the Binocular Progressive design simplified the fitting process. These lenses offer a highly effective solution for presbyopia correction, supported by robust clinical data and practitioner feedback.
Patient Satisfaction
MyDay Multifocal lenses demonstrate strong patient satisfaction due to their exceptional comfort and clear vision at all distances. The Aquaform Technology maintains hydration throughout the day, minimizing dryness and irritation. Patients report a smooth transition and adaptation, experiencing reduced visual disturbances like haloes and glare. This leads to increased overall satisfaction and improved quality of life for presbyopic contact lens wearers.

OptiExpert Support
OptiExpert provides comprehensive MyDay Multifocal fitting tools and resources, simplifying the process and maximizing success rates for practitioners and their patients.
Utilizing Fitting Tools
OptiExpert offers a suite of digital tools designed to streamline the MyDay Multifocal fitting process. These include interactive fitting guides, online calculators for initial power and add selection, and visual aids demonstrating the binocular progressive design.
Practitioners can leverage these resources to efficiently determine optimal lens parameters based on individual patient refraction and visual needs, ultimately enhancing the fitting experience and improving patient outcomes.
Accessing Resources
CooperVision provides comprehensive support materials for MyDay Multifocal fitting. Practitioners can find detailed fitting guides, clinical study data, and educational webinars on the OptiExpert platform.
Additional resources, including ordering information and lens parameter details, are readily available through CooperVision’s customer service and professional website, ensuring convenient access to all necessary fitting tools and support.

Digital Eye Strain & MyDay Energy
MyDay Energy lenses address digital eye strain symptoms, offering a solution for modern lifestyles and prolonged screen time with unique features.
Addressing Digital Eye Strain Symptoms
Digital eye strain, increasingly common, manifests as eye fatigue, blurred vision, and headaches from extended device use. MyDay Energy lenses are designed to combat these issues by incorporating innovative technology. This aims to reduce eye strain and enhance visual comfort during prolonged digital tasks.
The lenses offer a potential solution for patients experiencing discomfort, promoting a more natural and relaxed viewing experience throughout their digital day.
MyDay Energy Lens Features
MyDay Energy lenses utilize a unique design to address the specific visual demands of digital device use. They feature a central zone optimized for intermediate distances, crucial for computer screens and tablets. This innovative approach reduces eye strain by minimizing accommodation and refocusing efforts.
The lenses also maintain excellent peripheral vision and overall clarity, providing a comfortable and natural visual experience.

Multifocal Lens Surgery Comparison
MyDay Multifocal lenses offer a non-surgical alternative to multifocal lens surgery, providing a flexible option for vision correction and reduced eye strain.
MyDay Multifocal vs. Surgical Options
MyDay Multifocal lenses present a reversible and non-invasive solution compared to the permanent nature of multifocal lens surgery. Surgery involves risks and recovery time, while MyDay offers a trial period and adaptability.
Contact lenses suit individuals not ideal for surgery or those desiring a flexible vision correction method. MyDay addresses digital eye strain, a growing concern, without surgical intervention, providing a convenient alternative for clear vision.
Fitting Considerations for Existing Wearers
Transitioning from previous multifocals requires assessing habitual wear patterns and visual needs; MyDay Multifocal offers a potentially simpler fitting experience for these patients.
Transitioning from Previous Multifocals
Existing multifocal wearers often have established visual habits. A thorough assessment of their previous lens parameters – power, add, and material – is crucial. Understanding their reasons for switching, and any specific complaints with their current lenses, informs the MyDay Multifocal fitting.
Carefully evaluate their binocular vision and adaptation potential. A direct power transfer isn’t always ideal; subjective refinement is key to optimizing comfort and visual acuity. Consider a slightly different add power initially.
Habitual Lens Wearer Assessment
Habitual contact lens wearers demonstrate excellent compliance and handling skills, simplifying the fitting process. However, their corneal physiology may be altered. Assess tear film quality and corneal health meticulously. Determine their wearing time and any history of dryness or complications.
Understand their visual demands and lifestyle to tailor the MyDay Multifocal fitting. A comprehensive refraction, including monocular and binocular assessments, is essential for optimal outcomes.

Post-Fitting Follow-Up
Monitor lens performance and address patient concerns after dispensing MyDay Multifocal lenses. Ensure optimal vision, comfort, and adaptation are achieved promptly.
Monitoring Lens Performance
Regular follow-up appointments are crucial to assess the ongoing success of the MyDay Multifocal fitting. Evaluate visual acuity at distance, intermediate, and near, confirming the patient’s satisfaction with clarity.
Inquire about any reported symptoms like haloes, glare, or blurry vision, and address them proactively. Confirm lens comfort and wearing time, ensuring consistent daily wear. Assess overall adaptation and make adjustments if needed to optimize the patient’s experience.
Addressing Patient Concerns
Patient education is key to managing expectations and resolving issues. Thoroughly address any reported haloes, glare, or adaptation challenges with MyDay Multifocals.
Reassure patients that some initial adjustment is normal, and offer strategies for successful adaptation. Encourage open communication and prompt reporting of any discomfort or vision changes. Provide clear instructions for lens care and handling to ensure optimal performance.

Ordering and Availability
MyDay Multifocal lenses are available in a comprehensive range of parameters to meet diverse patient needs, ensuring a precise and comfortable fit.
Ordering information and specific lens details can be readily accessed through CooperVision’s professional resources.
Lens Parameters
MyDay Multifocal lenses feature a water content of 59% and are crafted from kalifilcon A, a silicone hydrogel material known for its breathability and comfort.
Available base curves range from 8.3mm to 8.6mm, with diameters of 14.4mm. Power ranges span from +0.50 to +6.00D, with add powers of +0;75, +1.00, +1.25, +1.50, +1.75, +2.00, and +2.50D, offering extensive customization for optimal vision correction.
Ordering Information
MyDay Multifocal lenses are readily available through authorized CooperVision distributors and eye care professionals. Ordering can be conveniently processed via online portals or through traditional ordering channels.
Practitioners can access detailed ordering guides and support through OptiExpert resources. Minimum order quantities may apply; packaging options include 30-pack and 90-pack configurations to suit practice and patient needs.
